Our Telx DAL1 and DAL2 data centers are guarded 24x365 and located in the heart of Dallas, Texas.  The sixth largest economy by output and the seventh overall largest by income, the metro region of Dallas-Fort Worth is a job producing machine.  The Dallas, TX Metroplex adds an average of 187 new jobs and 470 new residents daily, producing 23% of the state’s total output and maintaining 48% of Texas’ high-tech workforce. The Dallas-Fort Worth area is home to 18 Fortune 500 companies and 38 Fortune 1000 companies, 10 companies listed among America’s Largest Private Companies (Forbes, 2012) and 147 headquarters of companies employing at least 1,000 globally including A&T, Hunt Consolidated Oil and 7-Eleven. Doing business in the Dallas, TX area is also affordable, with a cost of living that’s 98.9% of the national average (Forbes, 2012).

View in Google Maps

The DAL1 - Telx Data Center

Google+

2323 Bryan St, Dallas, Texas 75201

For businesses in the Southwest, Telx® provides interconnection and colocation services from the heart of downtown Dallas at its 2323 Bryan Street data center location. One of the premier Internet gateways in North America, the state-of-the-art data center facilities in the Univision Tower are used by more than 60 carriers, making it a central interconnection and colocation hub for leading communications providers from North America, Latin America, Europe and Asia-Pacific countries.

Telx has established a Metro ConnectSM Solution between Bryan Street and adjacent data center Dallas facility at 8435 Stemmons Freeway to enable direct interconnectivity between all carriers colocated at these Telx Dallas data center locations.

Facility Specs

  • Building

    • 26 stories; 480,000 (sq.ft.)
  • Telx Leased

    • 35,036 (sq.ft.)
  • Flood Zone

    • Zone X (Unshaded): Outside 500 year flood plain
  • Seismic

    • Zone 1
  • Utility Power Capacity

    • 4,776 (kW)
  • UPS Power Capacity

    • 1,504 (kW)
  • UPS Redundancy

    • N, 2N
  • Power Density

    • 150-175 (W/sq.ft.)
  • DC Power Capacity

    • Available
  • Generator Power Capacity

    • 4,400 (kW) Shared
  • Generator Redundancy

    • N, N+1
  • Cooling Redundancy

    • N+1
  • Roof

    • Lower Roof-Modified Bitumen
    • Upper Roof-Single Membrane with Insulation
    • Roof Rights Available - ICB
  • Floor Loading

    • Up to 75 (lbs/sq.ft.)
  • Fiber and Building Entry

    • Multiple Diverse Entrances
  • Peering Exchanges

    • Telx Internet Exchange
  • Security

    • 24x7 Onsite Security Personnel
    • Monitored by CCTV Camera Systems
    • Biometric and Photo Badge Access Authentication Points for Data Center Entry
    • Security Check-In at Lobby and Loading Dock with Man Trap into the Data Center Suites
    • Elevator Authentication and Corridor Security
    • SOC2, SOC3, and HIPAA Compliant
  • Parking

    • Available

The DAL2 - Telx Data Center

Google+

8435 Stemmons Fwy, Dallas, Texas 75247

Telx® is the leading colocation and interconnection service provider within 8435 Stemmons Freeway, the most connected data center in the Dallas/Fort Worth area. 8435 Stemmons Freeway, better known as the First American Center, is one of two premier Telx colocation and interconnection facilities in Dallas and the entire Southwest.

Telx provides over 35,000 sq.ft. of colocation space as well as low latency direct access to hundreds of network operators located at Telx's Interconnection Center at 2323 Bryan Street (DAL1) via Telx's Metro ConnectSM solution, which provides data center and carrier customers with additional bandwidth and circuit options.

The DAL2 data center offers premier conditioned space as well as access control and state-of-the-art surveillance systems. DAL2 also complies with or exceeds International Telecommunication standards.

Facility Specs

  • Building

    • 11 stories; 230,700 (sq.ft.)
  • Telx Leased

    • 34,901 (sq.ft.)
  • Flood Zone

    • Zone X (Shaded): Outside 100 year flood plain
  • Seismic

    • Zone 1
  • Utility Power Capacity

    • 4,000 (kW)
  • UPS Power Capacity

    • 1,500 (kW)
  • UPS Redundancy

    • Distributed-Redundant 3:2
  • Power Density

    • 150 (W/sq.ft.)
  • DC Power Capacity

    • Available
  • Generator Power Capacity

    • 3,000 (kW)
  • Generator Redundancy

    • N+1
  • Cooling Redundancy

    • N+1
  • Roof

    • Single Membrane with Insulation
    • Roof Rights Available - ICB
  • Floor Loading

    • Up to 125 (lbs/sq.ft.)
  • Fiber and Building Entry

    • Multiple Diverse Entrances
  • Peering Exchanges

    • Telx Internet Exchange
  • Security

    • Monitored by CCTV Camera Systems
    • Biometric and Photo Badge Access Authentication Points for Data Center Entry
    • Security Check-In at Lobby and Loading Dock with Man Trap into the Data Center Suites
    • Elevator Authentication and Corridor Security
    • SOC2, SOC3, and HIPAA Compliant
  • Parking

    • Available